Investigation of the Effect of the Temporary Tissue Expander Used for Breast Reconstruction on Dose Distribution of Chest Wall Radiation

dc.contributor.authorCibiceli, S.
dc.contributor.authorÇatlı Dinç, S.
dc.contributor.authorErpolat, Ö. P.
dc.contributor.authorAkyol, O.
dc.contributor.authorMeriç, N.
dc.contributor.authorKarahacioğlu, E.
dc.contributor.departmentOthertr_TR
dc.contributor.facultyOthertr_TR
dc.date.accessioned2022-01-24T14:51:28Z
dc.date.available2022-01-24T14:51:28Z
dc.date.issued2018
dc.description.abstractThe rate of breast reconstruction after mastectomy is increasing in women with breast cancer. At the breast reconstruction, silicone implants or temporary tissue expanders (TTEs) are placed instead of breast tissue taken during mastectomy. It is unclear how TTEs which contain metallic structures and filled with saline, affect dose distribution during RT. For this reason, so that optimum RT planning can be performed, the effect of metallic port in the Mentor TTE of dose distribution has been examined in our study. MOSFET, NanoDot OSLD and EBT3 film dosimetric methods were used in the measurements. As a result of single frontal irradiation with metallic port made of samarium cobalt magnet and stainless steel, removed from the TTE, the maximum dose reduction rate at the bottom of the metallic port is 29.65% with NanoDot OSLD. The maximum dose increase rate over the metallic port is 6.25% with NanoDot OSLD. At the results obtained with measurements of 6 MV photon energy on rando phantom using TTE and silicone implant; for 3DCRT and IMRT treatment techniques, dose increase of less than 5% was observed on the over, right and left side of the metallic port with all dosimetric methods and the planning data. Under the metallic port, the rate of dose changes determined below 4% for these two treatment techniques. While using 9 MeV and 12 MeV electron energy, each dosimetric method and the data obtained from the treatment plans are evaluated in measurements dose increments of 12.63% with 9 MeV electrons and 10.66% with 12 MeV electrons were observed on the over, right and left side of the metallic port. While examining the measurements, due to scattering caused by metallic port while there were doses increasing over the metallic port, there were doses decreasing under the metallic port. But according to the changes in dose at the doses prescribed by international dosimetric protocols (±%5) at our study the change in dose observed with 3DCRT and IMRT techniques at 6 MV photon energy appears to be not large enough to affect tumor treatment provided that the metallic port is introduced into TPS. At the 9 MeV and 12 MeV incision scar electron boost treatments, the metallic port significantly increased the skin dose even though it was introduced to TPS.tr_TR
dc.description.indexYoktr_TR
dc.identifier.issue01tr_TR
dc.identifier.startpage4tr_TR
dc.identifier.urihttp://hdl.handle.net/20.500.12575/77214
dc.identifier.volume05tr_TR
dc.language.isoentr_TR
dc.publisherAnkara Üniversitesi Nükleer Bilimler Enstitüsütr_TR
dc.relation.journalJournal of Nuclear Sciencestr_TR
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıtr_TR
dc.subjectTemporary tissue expandertr_TR
dc.subjectMetallic porttr_TR
dc.subjectNanodot OSLDtr_TR
dc.subjectMOSFETtr_TR
dc.subjectEBT3 filmtr_TR
dc.titleInvestigation of the Effect of the Temporary Tissue Expander Used for Breast Reconstruction on Dose Distribution of Chest Wall Radiationtr_TR
dc.typeArticletr_TR

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Investigation of the Effect of the Temporary Tissue Expander Used for Breast Reconstruction on Dose Distribution of Chest Wall Radiation.pdf
Size:
1.35 MB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.62 KB
Format:
Item-specific license agreed upon to submission
Description: