Evaluation of temperature rise following the application of diode and ErCr:Ysgg lasers: an ex vivo study

dc.contributor.authorÖztürk, Adnan
dc.contributor.departmentDiş Hekimliği Fakültesitr_TR
dc.date.accessioned2020-12-04T09:03:11Z
dc.date.available2020-12-04T09:03:11Z
dc.date.issued2018
dc.description.abstractPurpose: Erbium, chromium: yttrium, scandium, gallium, garnet (ErCr:Ysgg) lasers have been frequently used in oral surgical procedures and are almost seen as alternatives to diode lasers. The aim of this comparative study was to analyze in an animal model the thermal elevation induced by ErCr:Ysgg and diode lasers in soft tissue and bone. Materials and methods: Thirty freshly dissected sheep mandibles containing bone and soft tissue were divided into 120 equal parts. Gallium-aluminum-arsenide (Ga-Al-As) diode laser (λ=940 nm) with 1, 2 and 5 W output powers and ErCr:Ysgg laser (λ=2780 nm) with 2.75, 4.5 and 6 W output powers were used on soft and bone tissues separately for 3 seconds with point application. Mean temperature values before and after application of the lasers were compared in soft tissue and bone. Results: The minimum mean temperature value was observed with 2.75 W ErCr:Ysgg laser while irradiation with 5 W diode laser created the maximum values (p<0.05). Conclusion: ErCr:Ysgg laser (λ=2780 nm) with 2.75 W power generates low levels of heat compared to diode lasers and may provide safer surgery in soft and bone tissues without destructive effects of temperature increase.tr_TR
dc.description.indexPubmed
dc.identifier.endpage136tr_TR
dc.identifier.issue3tr_TR
dc.identifier.startpage131tr_TR
dc.identifier.urihttps://doi.org/10.26650/eor.2018.479tr_TR
dc.identifier.urihttp://hdl.handle.net/20.500.12575/72535
dc.identifier.volume52tr_TR
dc.language.isoentr_TR
dc.relation.isversionof10.26650/eor.2018.479tr_TR
dc.relation.journalEur Oral Res .tr_TR
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıtr_TR
dc.subjectBonetr_TR
dc.subjectdiode lasertr_TR
dc.subjectsoft tissuetr_TR
dc.titleEvaluation of temperature rise following the application of diode and ErCr:Ysgg lasers: an ex vivo studytr_TR
dc.typeArticletr_TR

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
eor-52-3-131.pdf
Size:
642.85 KB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.62 KB
Format:
Item-specific license agreed upon to submission
Description: