Accuracy of linear and volumetric measurements of artificial ERR cavities by using CBCT images obtained at 4 different voxel sizes and measured by using 4 different software: an ex vivo research

dc.contributor.authorSönmez, Gül
dc.contributor.departmentDiş Hekimliği Fakültesitr_TR
dc.date.accessioned2020-12-30T12:56:04Z
dc.date.available2020-12-30T12:56:04Z
dc.date.issued2018
dc.description.abstractObjectives: To compare the accuracy of linear and volumetric measurements of artificial external root resorption (ERR) cavities by cone beam CT (CBCT) images obtained at four voxel sizes and by using four different software ex vivo. Methods: ERR cavities were created on 40 extracted single rooted anterior teeth. Images were obtained by using Planmeca CBCT unit at endo mode (0.075 mm); high-resolution mode (0.1 mm); high-definition mode (0.15 mm) and normal resolution mode (0.2 mm) voxel sizes. Images were analyzed by two observers using four different software (Romexis, 3D Doctor, ITK-SNAP, and OsiriX). (1) Diameter; (2) height; (3) depth; and (4) volume of the ERR were measured. CBCT measurements were then compared with direct physical measurements. ANOVA was used with general linear model analysis. The significance level was set at p < 0.05. Results: One-way ANOVA general linear model analysis showed no significant difference between or within observers for diameter, height, depth and volume measurements (p > 0.05). We found significant differences for diameter and volume measurements among softwares in terms of mean differences as compared to mean standard direct measurements (p < 0.05). We found statistically significant differences among voxel sizes and software for height measurements (p < 0.05). In addition, we found significant differences for diameter and volume measurements (p < 0.05) suggesting more accurate measurements for the cervical region when compared to apical region. Conclusions: Observers using CBCT images obtained at four voxel sizes performed similarly in the quantification of artificial ERR with clinically insignificant distinction between CBCT softwares used.tr_TR
dc.description.indexPubmed
dc.identifier.endpage10tr_TR
dc.identifier.issue8tr_TR
dc.identifier.startpage1tr_TR
dc.identifier.urihttps://doi.org/10.1259/dmfr.20170325tr_TR
dc.identifier.urihttp://hdl.handle.net/20.500.12575/72603
dc.identifier.volume47tr_TR
dc.language.isoentr_TR
dc.relation.isversionof10.1259/dmfr.20170325tr_TR
dc.relation.journalDentomaxillofac Radiol.tr_TR
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıtr_TR
dc.subjectroot resorptiontr_TR
dc.subjectcone-beam computerized tomographytr_TR
dc.subjectcomputer softwaretr_TR
dc.titleAccuracy of linear and volumetric measurements of artificial ERR cavities by using CBCT images obtained at 4 different voxel sizes and measured by using 4 different software: an ex vivo researchtr_TR
dc.typeArticletr_TR

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
dmfr.20170325.pdf
Size:
1.1 MB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.62 KB
Format:
Item-specific license agreed upon to submission
Description: