Comparison of the Effect of the Time Under the Three Primary Color Lighting of Led Production Before Scanning of Phosphorus Plates

dc.contributor.authorAmasya, Hakan
dc.contributor.authorOrhan, Kaan
dc.contributor.authorAlkan, Afra
dc.date.accessioned2025-02-07T06:32:42Z
dc.date.available2025-02-07T06:32:42Z
dc.date.issued2022
dc.description.abstractPurpose This study aims to compare the effect of light exposure in red, green and blue (RGB) colors prior to scanning of the PSP plates. Materials & Methods An Arduino-based system is produced for standardized light exposure to the irradiated PSP plates. The system consisted of an Arduino Mega 2560 developer board, 2 RGB LED light sources, a TSL2591 digital light sensor and a DHT11 temperature and humidity sensor. A light-tight platform is produced with additive manufacturing and electronical units are integrated into this platform. A two-step alloy was used to create contrast. PSP system (VistaScan, Dürr Dental, Germany) is irradiated with fixed parameters of 70 kV, 8 mA and 0.5 seconds. Scanning of the PSPs were delayed for 1-,3-,5-, and 10-minutes, and half of the active surfaces are exposed to RGB lights independently in full brightness (PWM) and calibrated with lux while the rest is protected. MGVs are measured in 6 regions per image. The MGV differences in regions between conditions were examined by Kruskal-Wallis test. A p-value<0.05 was considered statistically significant. Results In PWM setup, signal loss was higher in blue color at 1-,3-, and 5-minutes, but at 10-minutes, only the green light produced half-image. In LUX setup, signal loss was lower in green light. Contrast loss was lower in green light with LUX calibration. (p<0.05) Conclusion Among three colors compared, effect of exposure to green light prior to scanning of the irradiated PSP plates is found to be lower than the other colors
dc.identifier.urihttps://dspace.ankara.edu.tr/handle/20.500.12575/92287
dc.language.isoen
dc.publisherAnkara Üniversitesi
dc.subjectdigital radiology
dc.subjectmaterial science
dc.subjectphotostimulable phosphor plate
dc.titleComparison of the Effect of the Time Under the Three Primary Color Lighting of Led Production Before Scanning of Phosphorus Plates
dc.typeArticle

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
10.52037-eads.2022.0040-2711353.pdf
Size:
1.48 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: